Switch devices : AC, HomeEasy EU, ANSLUT¶
Overview¶
These devices are able to switch on and off some appliances. There are many models in various brands.
These devices can have several addresses set.
Configuration¶
When you create such a device, you will have to set the parameters for both the command and the sensor part. For a common usage, you will set the same values for the xPL command parameters and the xPL stat parameters.
xPL command parameters¶
Key | Type | Description |
---|---|---|
address | string | The device address (0x00000000 to 0x03ffffff). Example: 0x0038abfe |
unit | integer | The device unit (1..16). Example: 3 |
xPL stat parameters¶
Key | Type | Description |
---|---|---|
address | string | The device address (0x00000000 to 0x03ffffff). Example: 0x0038abfe |
unit | integer | The device unit (1..16). Example: 3 |
For both address and unit, you can use multiple values. This can be needed if you are controlling the light with several commands :
- a switch
- a remote control
- an open/close sensor
If you don’t set all the possible addreses, the device sensor status may not be updated on Domogik side!
Here is an example for the 0x0011223344 : 10 and 0x0044332211 : 8 :
- address = 0x0011223344|0x0044332211
- unit = 10|8
Configure the hardware device¶
You can set up the address and unit values for this kind of hardware devices. Here are the instructions for several models. Before doing this, you will have to create a Domogik device with the values you can freely choose for both address and unit parameters.
DI.O PDR-2300¶
Delete the learned addresses¶
Be careful, this will delete all the addresses learned by the hardware device!
Plug the module.
Call this command before the led stop blinking (there is currently no way to do this from Domogik administration):
dmg_send xpl-cmnd ac.basic "address=0x1,unit=1,command=group_off"
The plugged light should blink twice for acknowlegment.
Learn a new address¶
- Plug the module.
- Do this action before the led stop blinking : in Domogik administration, on your device details, for the command part, click on the On button of the switch command.
- The plugged light should blink twice for acknowlegment.
Chacon 54561, 54565, 54566, 54567, 54581, 54582, 54585, 54585¶
Delete the learned addresses¶
- Plug the module. Press the button until the led blinks (about 6 seconds).
- Press the button one more time.
- The plugged light should blink twice for acknowlegment.
Learn a new address¶
- Plug the module.
- Press the button.
- Do this action before the led stop blinking : in Domogik administration, on your device details, for the command part, click on the On button of the switch command.
- The plugged light should blink twice for acknowlegment.